logo
Rumah ProdukTimbangan Otomatis

Measurement Uncertainty in Weighing Systems: Principles and Best Practices for Metrological Accuracy

Measurement Uncertainty in Weighing Systems: Principles and Best Practices for Metrological Accuracy

  • Measurement Uncertainty in Weighing Systems: Principles and Best Practices for Metrological Accuracy
Measurement Uncertainty in Weighing Systems: Principles and Best Practices for Metrological Accuracy
Detail produk:
Place of Origin: CHINA
Model Number: Measurement Uncertainty in Weighing Systems
Syarat-syarat pembayaran & pengiriman:
Minimum Order Quantity: 1 set
Harga: Bisa dinegosiasikan
Packaging Details: Caron box
Delivery Time: 10-30days
Supply Ability: 2000 set per month
Kontak
Detil Deskripsi produk
Produk: Ketidakpastian pengukuran dalam sistem penimbangan Keterbacaan: 0,1μg hingga 1kg
Pengulangan: ± 0,01% hingga ± 0,5% dari beban Nonlinieritas: ± 0,02% hingga ± 0,2% FS
Histeresis: ± 0,01% hingga ± 0,1% FS Koefisien Suhu: 0,0001% hingga 0,01%/° C.
Daya apung udara: Hingga 0,1% Kesalahan Sensitivitas getaran: Gangguan 0,001% hingga 0,1%
Efek draft: Variasi 0,01% hingga 1% Berat minimum: 20-100 × Keterbacaan
Waktu penyelesaian: 2-30 detik Pemuatan eksentrik: Kesalahan 0,01% hingga 0,5%
Interval kalibrasi: Setiap hari untuk setiap tahun Kelas berat: E0 ke M3
Stabilitas: ± 0,5ppm ke ± 300ppm/tahun Sifat magnetik: <0,01% pengaruh
Ukuran sampel: 1-1000 pengukuran Mode penimbangan: Statis/dinamis
Ketidakpastian tare: ± 0,1% hingga ± 2%
Menyoroti:

automated checkweighing system

,

manufacturing load cell scale

,

Mettler Toledo weighing equipment

Measurement Uncertainty in Weighing Systems: Principles and Best Practices for Metrological Accuracy
Key Specifications
Attribute Value
Readability 0.1μg to 1kg
Repeatability ±0.01% to ±0.5% of load
Nonlinearity ±0.02% to ±0.2% FS
Hysteresis ±0.01% to ±0.1% FS
Temperature Coefficient 0.0001% to 0.01%/°C
Air Buoyancy Up to 0.1% error
Vibration Sensitivity 0.001% to 0.1% disturbance
Draft Effects 0.01% to 1% variation
Minimum Weight 20-100*readability
Introduction to Measurement Uncertainty in Weighing
Measurement uncertainty is a fundamental concept in metrology that quantifies the doubt associated with weighing results. In precision weighing systems, understanding and managing uncertainty is critical for:
  • Ensuring compliance with international standards (ISO/IEC 17025, OIML R76)
  • Maintaining quality control in regulated industries
  • Making reliable pass/fail decisions in checkweighing applications
  • Validating weighing processes for GMP and FDA compliance
Best Practices for Uncertainty Management
Calibration and Maintenance
  • Perform regular calibrations using traceable mass standards (Class E2 or better)
  • Implement daily verification checks with control weights
  • Maintain environmental logs (temperature, humidity, barometric pressure)
  • Follow manufacturer's preventive maintenance schedule
Operational Controls
  • Allow proper warm-up time (typically 30-60 minutes for analytical balances)
  • Use anti-static devices for powders and light materials
  • Implement proper leveling procedures
  • Establish standard operating procedures (SOPs) for weighing processes
Advanced Techniques
  • Automated weighing systems to eliminate operator influence
  • Statistical process control (SPC) for trend monitoring
  • Monte Carlo simulations for complex uncertainty analysis
  • Digital filtering algorithms to reduce electronic noise
Conclusion
Effective measurement uncertainty management in weighing systems requires:
  • Comprehensive understanding of all uncertainty sources
  • Proper system selection matched to application requirements
  • Rigorous calibration and maintenance programs
  • Operator training and standardized procedures
  • Continuous monitoring and improvement processes
By implementing these best practices, organizations can achieve metrological accuracy that meets both technical requirements and regulatory expectations while optimizing quality control processes.
Measurement Uncertainty in Weighing Systems: Principles and Best Practices for Metrological Accuracy 0

Rincian kontak
SMARTWEIGH INSTRUMENT CO.,LTD

Kontak Person: Shirley

Tel: +86-15851932889

Faks: 86-519-68781609

Mengirimkan permintaan Anda secara langsung kepada kami (0 / 3000)

Produk lainnya