logo
Rumah ProdukTimbangan Otomatis

Inspection Procedures for Industrial Weighing Systems

Inspection Procedures for Industrial Weighing Systems

Detail produk:
Tempat asal: CINA
Nomor model: Prosedur Inspeksi untuk Sistem Penimbangan Industri
Syarat-syarat pembayaran & pengiriman:
Kuantitas min Order: 1 set
Harga: Bisa dinegosiasikan
Kemasan rincian: Kotak Caron
Waktu pengiriman: 10-30 hari
Menyediakan kemampuan: 2000 set per bulan
Kontak
Detil Deskripsi produk
Product: Inspection Procedures for Industrial Weighing Systems Weighing Range: Min: 0.1 kg – Max: 50,000 kg (varies by model)
Tolerance (Error Limit): ±0.1% of reading (for Class III) or ±1 division (whichever is stricter) Frequency: Every 6 months (or after 500 hours of operation)
Calibration Weights: Class F1/M1 (OIML R111) with valid certification Temperature Range: -10°C to +40°C (operational), -20°C to +60°C (storage)
Humidity Tolerance: 10% to 90% RH (non-condensing) Load Cell Type: Strain gauge (standard), Capacitive (high precision)
Overload Protection: 150% of max capacity (safety limit) Power Supply: 110–240V AC, 50/60Hz or 24V DC (±5%)
EMC/EMI Resistance: Complies with EN 61326-1 (industrial EMC standards) Repeatability: ±0.05% of applied load (test with 10 repeated measurements)
Linearity Error: ±0.2% of full scale Material Safety: Stainless steel (Grade 316) for corrosive environments
Legal-for-Trade: NTEP, MID (EU), OIML certification (if used in commerce) Calibration Certificate: Must include date, technician, uncertainty, traceability
User Manual: Must cover installation, operation, maintenance, troubleshooting
Menyoroti:

industrial weighing system inspection

,

load cell inspection procedures

,

Mettler Toledo weighing system maintenance

Inspection Procedures for Industrial Weighing Systems
Comprehensive inspection procedures for industrial weighing systems to ensure accuracy, safety, and compliance with industry standards.
Technical Specifications
Attribute Value
Weighing Range Min: 0.1 kg – Max: 50,000 kg (varies by model)
Tolerance (Error Limit) ±0.1% of reading (for Class III) or ±1 division (whichever is stricter)
Frequency Every 6 months (or after 500 hours of operation)
Calibration Weights Class F1/M1 (OIML R111) with valid certification
Temperature Range -10°C to +40°C (operational), -20°C to +60°C (storage)
Humidity Tolerance 10% to 90% RH (non-condensing)
Load Cell Type Strain gauge (standard), Capacitive (high precision)
Overload Protection 150% of max capacity (safety limit)
Power Supply 110–240V AC, 50/60Hz or 24V DC (±5%)
EMC/EMI Resistance Complies with EN 61326-1 (industrial EMC standards)
Inspection Process Overview
Industrial weighing system inspections involve evaluating mechanical integrity, electronic performance, and overall functionality to maintain measurement reliability and compliance.
Pre-Inspection Checks
  • Visual Inspection: Examine for damage, wear, or corrosion on platform and support structure
  • Cable and Connection Check: Verify all connections are secure and undamaged
  • Foundation and Environment: Assess for stability and environmental factors affecting performance
Calibration and Verification
  • Zero Balance Check: Verify stable zero reading with no load
  • Span Calibration: Test accuracy across weighing range using certified test weights
  • Repeatability Test: Confirm consistent readings with repeated measurements
Functional and Operational Tests
  • Load Cell Performance: Verify proper function and balanced outputs
  • Indicator and Software Check: Test display functionality and data transmission
  • Safety and Overload Test: Confirm proper activation of overload protection
Inspection Procedures for Industrial Weighing Systems 0

Rincian kontak
SMARTWEIGH INSTRUMENT CO.,LTD

Kontak Person: Mrs. Shirley

Tel: +86-15851932889

Faks: 86-519-68781609

Mengirimkan permintaan Anda secara langsung kepada kami (0 / 3000)

Produk lainnya